Zappi Not Connecting to Solar? Complete UK Fix Guide 2025
Your Zappi charger won't detect your solar panels and ECO+ mode isn't working. You installed solar specifically to charge your EV for free, but the Zappi just charges from the grid.
Good news: 75% of UK Zappi solar issues are simple configuration problems, not hardware faults. Most fix in 15-30 minutes with £0 cost.
Let's get your Zappi seeing that free solar energy.
Quick 3-Minute Diagnostic
Before diving deep, check these three things:
- Check Zappi display (30 seconds) - Does it show any solar generation? (sun icon with watts)
- Check CT clamp position (1 minute) - Is it on the correct cable? Arrow pointing right direction?
- Check ECO+ mode (30 seconds) - Is it enabled in the Zappi menu?
↳ Most Common Cause: CT clamp installed backwards or on wrong cable - 45% of UK cases
Understanding Zappi Solar Detection
How Zappi Detects Solar:
The Zappi needs to KNOW how much solar you're generating. It can't guess. Two methods:
Method 1: CT Clamp (Wired)
- Small sensor clamps around your meter tail cable
- Measures current flowing to/from grid
- Zappi calculates: Solar Generation = House Use - Grid Import
- Most common UK setup (90% of installations)
Method 2: Harvi (Wireless)
- Wireless sensor at consumer unit
- Sends generation data via radio (868 MHz)
- Requires Zappi Hub for communication
- Less common (10% of UK installations)
What ECO+ Mode Does:
- Monitors solar generation in real-time
- Only charges when excess solar available
- Adjusts charge rate (1.4kW to 7.4kW) to match solar surplus
- Stops charging if solar drops (clouds)
If Zappi shows NO solar generation, it won't use ECO+ mode (assumes no solar available).
Fix 1: CT Clamp Installed Backwards (45% of Cases)
Why This Happens:
CT clamps are directional. They measure current flow direction. If arrow points wrong way, Zappi sees NEGATIVE solar (thinks you're exporting when importing).
This is THE most common issue UK installers report.
Symptoms:
- Zappi shows NO solar generation (0W)
- Or shows negative values
- ECO+ mode never activates
- Your inverter shows solar generating fine
How to Fix:
Step 1: Locate CT Clamp
- Open consumer unit door (turn off main switch first!)
- Find CT clamp (grey plastic clip around thick cable)
- Should be on meter tail (cable from meter to consumer unit)
Step 2: Check Arrow Direction
- CT clamp has arrow printed on it
- Arrow should point FROM meter TOWARDS consumer unit
- Think: "Arrow follows power flow into house"
Step 3: Flip if Wrong
- Unclip CT clamp (squeeze to open)
- Rotate 180 degrees
- Reclip around same cable
- Arrow now points correct direction
Step 4: Check Zappi Display
- Close consumer unit
- Turn main switch back on
- Go to Zappi display
- Wait 10 seconds
- Should now show solar generation (sun icon with watts)
⚠️ Safety:
- Turn OFF main isolator before touching anything in consumer unit
- If uncomfortable, call your installer (£0 if within warranty, £80-150 callout)
Time: 5-10 minutes
Cost: £0
Success Rate: 45% of cases resolve with this
Fix 2: CT Clamp on Wrong Cable (25% of Cases)
Why This Happens:
Your consumer unit has multiple thick cables. Installer may have clamped:
- Solar inverter cable (wrong - measures GENERATION not grid)
- Individual circuit cable (wrong - too small a picture)
- Shower/cooker cable (wrong - no relationship to grid)
Correct location: Meter tail between electricity meter and consumer unit main switch.
Symptoms:
- Zappi shows solar generation that doesn't match inverter
- Shows generation at night (impossible!)
- ECO+ mode behaves erratically
How to Fix:
Step 1: Identify Meter Tail
- Turn off main isolator
- Locate electricity meter (usually near front door or under stairs)
- Follow thick cable FROM meter TO consumer unit
- This is the meter tail (usually 16-25mm cable, thickest in consumer unit)
Step 2: Move CT Clamp
- Remove CT clamp from current position
- Place around meter tail cable
- Arrow points from meter towards consumer unit
- Clip firmly shut
Step 3: Verify
- Turn main switch back on
- Check Zappi display
- Solar generation should now match your inverter display (±10%)
💡 Tip: Take photo of your inverter display showing generation. Compare to Zappi display. Should be similar.
Time: 10-15 minutes
Cost: £0
Success Rate: 25% of cases
Fix 3: CT Clamp Not Plugged In (12% of Cases)
Why This Happens:
CT clamp connects to Zappi with small 3.5mm audio jack cable. Connection can work loose during installation or over time.
Symptoms:
- Zappi shows "CT Err" or "No CT" message
- OR shows zero solar generation always
- ECO+ mode greyed out/unavailable
How to Fix:
Step 1: Check Connection
- Look at bottom of Zappi unit
- Find small socket labeled "CT1" (looks like headphone jack)
- Is cable plugged in fully?
Step 2: Reseat Cable
- Unplug CT cable from Zappi
- Check connector - any damage? Bent pins?
- Firmly push back into CT1 socket (should click)
Step 3: Check Cable Route
- Follow cable from Zappi to consumer unit
- Any damage? Cuts? Pinched by something?
- Cable should have slack (not pulled tight)
If Cable Damaged:
- Replacement CT cables: £20-30 from myenergi shop
- Or call installer to replace (£80-150 callout)
Time: 5 minutes
Cost: £0 (reseating), £20-30 (new cable)
Success Rate: 12% of cases
Fix 4: Zappi Not Set to ECO+ Mode (10% of Cases)
Why This Happens:
ECO+ mode isn't default. You or installer must enable it. Sometimes disabled accidentally or after firmware update.
Symptoms:
- Zappi shows solar generation correctly
- But charges at full speed from grid
- Doesn't adjust based on solar
How to Enable ECO+ Mode:
On Zappi Unit:
- Press center button (wakes display)
- Rotate dial to "Charge Mode" option
- Press button to select
- Rotate to "ECO+" (not ECO, not FAST)
- Press button to confirm
- Display shows green sun icon = ECO+ active
In myenergi App:
- Open app (iOS/Android)
- Select your Zappi
- Tap "Charge Mode" at top
- Select "ECO+"
- Confirm
Difference Between ECO and ECO+:
| Mode | What It Does | When to Use |
|---|---|---|
| FAST | Charges at max speed from any source | When you need full charge quickly |
| ECO | Charges when 1.4kW+ solar available | Minimum 6A charging (slow but free) |
| ECO+ | Charges when ANY solar available | Uses solar + grid to maintain minimum 6A |
Most UK users want ECO+ (hybrid mode - uses solar when available, tops up from grid if needed).
Time: 2 minutes
Cost: £0
Success Rate: 10% of cases
Fix 5: Harvi Not Paired with Hub (5% of Cases)
Why This Matters:
If you have Harvi (wireless sensor), it must communicate with Zappi Hub. Hub then tells Zappi about solar generation.
Symptoms:
- You have Harvi sensor (small box with antenna in consumer unit)
- Zappi shows no solar generation
- Hub installed but not configured
How to Pair Harvi:
Step 1: Check Hub Power
- Find Zappi Hub (small grey box, usually near internet router)
- Plugged into mains socket?
- Green LED on?
Step 2: Check Hub Connection to Zappi
- Hub connects to Zappi via powerline (through house wiring)
- In myenergi app: Settings > Devices > Should show Hub + Harvi
Step 3: Re-Pair Harvi
- Open myenergi app
- Go to Settings > Devices
- Select Hub
- Tap "Add Harvi" or "Re-pair Harvi"
- Press button on Harvi unit (in consumer unit - small button on side)
- Hold 5 seconds until LED flashes
- App should confirm "Harvi Found"
- Check Zappi display - should show solar generation within 30 seconds
⚠️ If Still Not Working:
- Check Harvi battery (CR2032 coin cell, lasts 2-3 years)
- Check Hub firmware (app > Settings > Hub > Firmware version)
- Hub may need replacement (rare, £80-120)
Time: 10-15 minutes
Cost: £0 (pairing), £3-5 (battery if needed)
Success Rate: 5% of Zappi users (Harvi less common than CT clamp)
Fix 6: Phase Mismatch (Single vs Three-Phase) (2% of Cases)
Why This Happens:
UK homes are usually single-phase. But some have three-phase supply. If CT clamp is on wrong phase, Zappi won't see accurate generation.
Symptoms:
- Solar generation shown is wrong (way too high or too low)
- ECO+ mode charges erratically
- Only affects three-phase homes
How to Check:
Do you have three-phase?
- Look at your main isolator in consumer unit
- Single-phase: 1 or 2 switches (100A typical)
- Three-phase: 3 switches side-by-side
If Three-Phase:
- CT clamp must be on same phase as Zappi
- OR use all three CT clamps (CT1, CT2, CT3) for accurate total
- This is complex - call installer
Solution:
- Electrician must verify Zappi and CT clamp on same phase
- Or configure Zappi for three-phase monitoring (requires all 3 CT clamps)
- Cost: £120-250 for electrician to reconfigure
Time: 1-2 hours (electrician visit)
Cost: £120-250
Success Rate: Only applies to 2% of UK homes with three-phase
Fix 7: Firmware Bug (Rare, 1% of Cases)
Why This Is Last:
Myenergi regularly updates Zappi firmware. Occasionally a bug breaks solar detection. Very rare but happens.
Symptoms:
- None of above fixes work
- Solar generation was working, suddenly stopped
- Recent firmware update (check app)
How to Fix:
Step 1: Check Firmware Version
- Open myenergi app
- Settings > Zappi > Firmware Version
- Note version number (e.g., "V2.120")
Step 2: Search for Known Issues
- Check myenergi forum: https://myenergi.info/
- Search "Zappi V[your version] solar not working"
- See if others report same issue
Step 3: Roll Back or Update
- If known bug: Wait for myenergi fix (usually 2-4 weeks)
- Or roll back: App > Settings > Zappi > Firmware > "Revert to Previous"
- Or update: If newer firmware available, update and test
Step 4: Contact Myenergi Support
- UK Support: 01422 880 100
- Email: support@myenergi.com
- They can remote-diagnose via app
- Usually respond within 24-48 hours
Time: 1-3 days (waiting for support response)
Cost: £0 (under warranty), £80-150 (out of warranty diagnosis)
Success Rate: <1% of cases (very rare)
When to Call for Help
You Can Fix Yourself:
✅ CT clamp direction (Fix 1)
✅ CT clamp position (Fix 2)
✅ Cable connections (Fix 3)
✅ ECO+ mode enable (Fix 4)
✅ Harvi pairing (Fix 5)
Need Electrician:
⚡ CT clamp in consumer unit (if uncomfortable)
⚡ Three-phase configuration
⚡ Damaged CT cable replacement
⚡ New CT clamp installation
Cost: £80-150 callout
Need Myenergi Support:
🔧 Firmware issues
🔧 Hub/Harvi hardware faults
🔧 Zappi showing error codes
🔧 None of above fixes work
Cost: £0 (3-year warranty), £80-150 (out of warranty)
Prevention: Keep Zappi Detecting Solar
Monthly Checks (5 minutes):
- Verify solar generation displays on Zappi
- Compare Zappi vs inverter (should match ±10%)
- Test ECO+ mode (check it adjusts charge rate with clouds)
- Check CT clamp cable - still firmly connected?
Every 6 Months:
- Check CT clamp position - hasn't moved?
- Update Zappi firmware (myenergi app)
- Test in different weather (sunny day vs cloudy)
- Clean Zappi display (easier to read generation)
What Causes Zappi Solar Issues:
❌ CT clamp vibrates loose (traffic/heavy doors slamming)
❌ Firmware updates reset ECO+ mode
❌ Consumer unit work moves CT clamp
❌ Harvi battery dies (2-3 years)
❌ Electrician doing other work unplugs CT cable
✅ Annual electrical inspection catches issues early
✅ Label CT cable ("Zappi CT - DO NOT REMOVE")
✅ Keep myenergi app updated
Real UK Owner Experience
Owner: ZappiUser_Cornwall, myenergi Forum, January 2025
"My Zappi stopped seeing solar after an electrician did some consumer unit work. He'd moved my CT clamp to a different cable (thought it was in the way). Took me 2 hours of head-scratching before I checked.
Moved CT clamp back to meter tail, bingo - solar generation appeared again. Electrician apologized, said he didn't realize what the clamp was for. Now I've labeled the cable 'ZAPPI SENSOR - DO NOT MOVE'. Lesson learned!"
Outcome: CT clamp repositioned, £0 cost, 10 minutes fix
Quick FAQ
1. My Zappi shows solar but ECO+ still won't charge. Why?
Check minimum charge threshold. ECO+ needs minimum 1.4kW solar to start charging (6A at 230V). If your solar generates less, Zappi waits. Also check: Is your car battery already full? Car won't accept charge if at target SOC. Try lowering target to 80% in car settings.
2. Can I use Zappi without solar monitoring?
Yes, absolutely. Just use FAST mode (charges at full speed from grid). You lose solar optimization but Zappi works fine as regular charger. Many users start with FAST, add solar monitoring later.
3. Do I need Harvi or will CT clamp work?
CT clamp is standard and works for 95% of UK homes. Only need Harvi if: Consumer unit too far from Zappi (>10m cable run difficult), or you want wireless convenience. CT clamp is simpler and more reliable.
4. My solar inverter shows 3kW but Zappi shows 2.5kW. Is this wrong?
This is normal. Zappi measures at the meter (after house consumption). If house using 500W, Zappi sees 3kW generation - 500W house use = 2.5kW excess. Both readings are correct, different measurement points.
5. Does Zappi work with battery storage (Powerwall, GivEnergy)?
Yes, but needs careful CT clamp placement. CT must measure grid import/export, not battery charge/discharge. Consult installer - battery systems need specific CT configuration. May need two CT clamps (one for grid, one for battery).
6. Can I test if my CT clamp works without solar?
Yes - kettle test: Turn off all house loads. Turn on 3kW kettle. Zappi should show ~3kW import (negative generation). If Zappi shows nothing, CT clamp not working. If shows positive 3kW, CT clamp backwards.
Summary: Your Zappi Solar Fix Action Plan
If Zappi won't detect solar, start here:
- ✅ Check CT clamp arrow direction (Fix 1 - 45% success, 5-10 mins)
- ✅ Verify CT clamp on meter tail (Fix 2 - 25% success, 10-15 mins)
- ✅ Check CT cable plugged into Zappi (Fix 3 - 12% success, 5 mins)
- ✅ Enable ECO+ mode (Fix 4 - 10% success, 2 mins)
- ✅ Test at different solar levels (morning vs midday vs cloudy)
Most UK Zappi owners fix solar detection with Steps 1 or 2 (total time: 10-20 minutes, £0 cost).
If still not working: Contact myenergi support (01422 880 100) or your installer (free if within warranty period).
Join UK Zappi community: myenergi Forum - 15,000+ UK users sharing real-time solutions.